Analysis of vertical movements of the permanent GNSS‒station POLV on the base of satellite data and leveling
Item ID: 20294
1 Media file
2025/12/17
Citation
eNUPPIR (). Analysis of vertical movements of the permanent GNSS‒station POLV on the base of satellite data and leveling. https://os4.nupp.edu.ua/document/item-22759
eNUPPIR. "Analysis of vertical movements of the permanent GNSS‒station POLV on the base of satellite data and leveling." Web. . <https://os4.nupp.edu.ua/document/item-22759>.
eNUPPIR. "Analysis of vertical movements of the permanent GNSS‒station POLV on the base of satellite data and leveling." Accessed . https://os4.nupp.edu.ua/document/item-22759.
Copied to clipboard
Властивості
Тип
Українська
Назва
Англійська
Analysis of vertical movements of the permanent GNSS‒station POLV on the base of satellite data and leveling
Українська
Аналіз вертикальних рухів перманентної ГНСС-станції POLV на основі супутникових даних та нівелювання
Автор
Опис
Англійська
The purpose of this work is to analyze the results of the study of the dynamics of vertical movements of the permanent station of the GNSS positioning system «Poltava» (identifier POLV). Method. A geodynamic test site was set up on the territory of the Poltava Gravimetric Observatory. It includes rappers with known stability indicators, which are laid at different depths. The exact level of H‒05 is set on the A1 standard, which is characterized by high stability over 30 years of observations. The GNSS station, the vertical movements of which were studied, is installed on a specially built pedestal on the inner capital wall of the laboratory building of the Poltava Gravimetric Observatory of the S. I. Subbotin Institute of Geophysics of the National Academy of Sciences of Ukraine. The dynamics of the movement of the base station were monitored by marks placed on the edges of the western and eastern sides of the laboratory building. To evaluate and compare the obtained results, the processing of satellite data was carried out by the method of approximation of polynomial smoothing of the third degree. The results. According to the results of periodic geometric leveling, it was established that for the period 2004–2019, the slow vertical movements of the stamps were 1.03–1.11 mm with an average annual rate of rise of 0.065–0.07 mm/year. Seasonal vertical movements of the permanent GNSS station POLV are within 2 mm/year, and in the first half of the year there is a rise of the point, and in the second - its decline. Selected components that can affect the vertical movements of a GNSS station installed on an engineering structure. A comparison of the results of ground and satellite observations was made for the periods of 2004-2005 and 2018-2019. Based on the observations and modeling, the component of vertical oscillations of the receiving antenna obtained in the period of 2004-2005 by both ground and satellite methods did not exceed 2 mm; in the period of 2018-2019, the analysis of satellite data showed an increase in fluctuations up to 7 mm, this can be explained by a large spread of satellite measurements. Scientific novelty and practical significance lie in the detected stability of the amplitude of vertical movements of the GNSS station, which was confirmed by the ground method of geometric leveling and the analysis of time series of satellite observations. The conducted studies confirm the influence of various factors on the stability of receiving antennas.
Метою цієї роботи є аналіз результатів дослідження динаміки вертикальних рухів перманентної станції системи позиціонування GNSS «Полтава» (ідентифікатор POLV). Метод. На території Полтавської гравіметричної обсерваторії було створено геодинамічний випробувальний майданчик. Він включає репери з відомими показниками стійкості, закладені на різній глибині. Точний рівень H‒05 встановлено на стандарті А1, який характеризується високою стійкістю протягом 30 років спостережень. Станція GNSS, вертикальні рухи якої досліджувалися, встановлена на спеціально побудованому постаменті на внутрішній капітальній стіні лабораторного корпусу Полтавської гравіметричної обсерваторії Інституту геофізики імені С. І. Субботіна Національної академії наук України. Динаміка рухів базової станції контролювалася за мітками, розміщеними на краях західної та східної сторін лабораторного корпусу.
Мова
Дата випуску
Тематика
Англійська
Англійська
Англійська
Англійська
Англійська
Англійська
Українська
Англійська
Українська
Українська
Українська
Видавництво
Бібліографічний опис
Українська
Nesterenko S.V. Analysis of vertical movements of the permanent GNSS‒station POLV on the base of satellite data and leveling / S.V. Nesterenko, V.G. Pavlyk, R.А. Mishchenko // Geodesy, cartography and aerial photography : Interdepartmental scientific and technical collection. – 2023. – Vol. 97. – Р. 46–55. – https://doi.org/10.23939/istcgcap2023.97.046
УДК
528.482:528.016.1
Набори елементів 1
Медіа
Metadata Information
Створено
2025-12-17 11:01
Last Modified
2025-12-17 11:01
Date Issued (DC)
2023
Item ID
#20294
Resource Template
Наукова стаття